Water Heater Repair
Tank & Tankless Service · Fast Diagnostics · All Fuel Types
Our Approach to Water Heater Repair
How a Tank Water Heater Works
- Cold inlet — the dip tube carries it to the tank bottom
- Burner — heats water at the bottom of the tank
- Anode rod — sacrificial rod that fights corrosion
- T&P valve — releases pressure if it builds too high
- Hot outlet — draws the hottest water from the top
No hot water is never convenient. J&R Mechanical Services diagnoses and repairs water heater issues quickly and accurately — getting your hot water back on as fast as possible.
Common water heater problems include no hot water, inconsistent temperatures, strange noises, leaking, pilot light issues, and error codes on tankless units. Our technicians can quickly identify the problem and recommend the most cost-effective solution. If your water heater is leaking, our leak repair specialists can address any water damage at the same time.
We repair both tank and tankless water heaters from all major manufacturers. Common repairs include thermocouple replacement, heating element replacement, thermostat repair, anode rod replacement, and descaling for tankless units.
If your water heater is leaking from the tank or the cost of repair exceeds half the price of replacement, we will be honest about recommending a new unit — whether that is a traditional tank or a tankless system. We help you weigh the options without pressure.
No Hot Water? Check These Things First
Before you call anyone, a quick check can save you a service visit. Gas or propane heater: confirm the gas valve is on and the pilot or ignition status light is behaving normally. Tankless unit: note any error code on the display — it tells us exactly where to start. If hot water is merely lukewarm or runs out fast, a failed heating element, a stuck dip tube, or heavy sediment are the usual suspects.
If those checks do not bring the hot water back, call us at (207) 902-8899. We arrive with the common failure parts for major brands on the truck, so most repairs are finished in a single visit.
Repair or Replace? How We Make the Call
The decision comes down to three things: where the leak or failure is, the age of the unit, and the repair cost. Water coming from the tank body itself means internal corrosion — no repair fixes that, and replacement is the only honest recommendation. Water at a fitting, valve, or element gasket is usually a simple, inexpensive repair. On age: a modest repair on a newer heater is obviously worth it; the same repair on a much older tank is money spent on borrowed time, and we will say so.
Our technicians have zero incentive to condemn a repairable unit. We show you what failed, price both paths when both are viable, and let you choose. That is how we turn a one-time repair call into a customer for life.
Water Heater Troubleshooting and Diagnostic Guide
The same symptom can mean two different things depending on whether a water heater runs on gas, propane, or electricity, and modern gas water heaters add a second layer of information: a status light on the gas control valve that blinks in a pattern the manufacturer defines. Reading that pattern correctly, on the correct model, narrows a repair before a technician ever opens a panel.
The tables below come from three manufacturers' own service documentation for named model lines — not a generalized list. A status light pattern from one brand's valve does not carry over to another brand's valve, and in some cases not even to a different generation of the same brand's valve.
Symptoms by Fuel Type
Below are the five most common complaints and what typically causes each one, split by fuel type where the cause actually differs. Gas and propane units behave the same way for troubleshooting purposes; the meaningful split is gas/propane versus electric. Tankless units share some of these symptoms too, but they diagnose themselves with a specific error code rather than presenting as a vague symptom — see our tankless water heater guide for brand-by-brand code tables.
| Symptom | Gas or propane units | Electric units |
|---|---|---|
| No hot water at all | Pilot or igniter failed to light, or the unit locked out after repeated failed ignition attempts. | A tripped breaker, or a failed high-limit (thermal cutoff) switch — often triggered after a heating element failed. |
| Hot water is lukewarm or runs out quickly | Heavy sediment on the tank bottom insulating the burner from the water, or a thermostat set too low. | A failed lower heating element (you get a partial tank of hot water before it goes cold), or a broken dip tube letting cold water mix into the hot outlet. |
| Rumbling or popping sounds | Sediment on the tank bottom trapping pockets of water that boil and pop under the burner. | Same cause — sediment trapped under or around the lower heating element. |
| Water leaking | Water at a fitting, valve, or gasket is usually repairable. Water seeping from the tank shell itself means the inner tank has corroded through — not repairable. | Same distinction applies: fitting/valve leaks are repairable, a leak from the tank body is not. |
| Sulfur or rotten-egg smell from the hot tap | Usually the magnesium anode rod reacting with sulfate-reducing bacteria in the water — not a fuel-related fault. | Same cause, and it's more common on private well water than on chlorinated public supply. |
Reading a Gas Control Valve's Status Light
Most modern gas tank water heaters use an integrated gas control valve with a small LED that blinks in a defined pattern — a number of flashes, sometimes followed by a pause and a second set of flashes, sometimes a solid light or no light at all. Manufacturers assign these patterns per valve generation, so the tables below apply to the specific valve families named, not to gas water heaters generally. Two or three manufacturers often source the same underlying control from a supplier like Robertshaw or White Rodgers, but each brand documents its own condition list for it, which is why we always confirm the brand and generation before reading a code.
Rheem and Ruud — Robertshaw Gas Control (Guardian PowerVent)
Rheem's technical service bulletins document the Robertshaw gas control used on Guardian PowerVent residential gas water heaters. The green LED's flash pattern is read as a primary pattern, then (after a one-second pause) a secondary pattern.
| Primary / secondary flash pattern | Condition | What it means |
|---|---|---|
| Slow blink / none | Stand-by | Normal operation — water is hot and the unit is waiting. |
| Fast blink / none | Call for heat | Normal operation — the blower should be running. |
| Solid ON / none | Internal control failure or miswiring | A problem with the valve's internal electronics, or a disconnected thermistor/ECO. |
| 1 flash / 1 flash | Ignition failure | No flame detected after three ignition attempts. Checks include gas supply, gas pressure, and spark at the igniter. |
| 2 flashes / 1 flash | Flammable vapors detected | The flammable-vapor sensor tripped. Requires a professional — never bypass this sensor. |
| 3 flashes / 1 flash | Vacuum switch fails to open | A safety switch related to venting is stuck closed. |
| 3 flashes / 3 flashes | Vacuum switch fails to close | Often caused by blocked or restricted venting. |
| 4 flashes / 1 flash | Line/neutral polarity failure | Reversed polarity at the outlet or power connection. |
| 4 flashes / 2 flashes | ECO (over-temperature) failure | Water temperature exceeded the safety limit and the one-time cutoff tripped. |
| 4 flashes / 3 flashes | False flame detected | The control senses flame with the gas valve off. |
| 5 flashes | Vacation mode | Not a fault — the thermostat dial is set to its lowest position. |
Rheem and Ruud — White Rodgers Intelli-Vent Control
Since 2007, Rheem transitioned standard Guardian PowerVent residential gas water heaters (natural gas and propane) to the White Rodgers Intelli-Vent control, which displays a numbered error rather than a flash-counted pattern.
| Error | Condition | What it means |
|---|---|---|
| Error 1 | Open earth ground | The water heater's grounding connection is open or disconnected. |
| Error 2 | Wiring fault | Self-diagnostic detected a wiring error or high resistance to ground. |
| Error 3 | Pressure switch stuck closed | The switch didn't open within 5 seconds of a call for heat. |
| Error 4 | Pressure switch stuck open | Often caused by disconnected tubing or blocked/restricted venting. |
| Error 5 | Igniter circuit fault | Hot surface igniter resistance is out of range or the wiring harness is loose. |
| Error 6 | Ignition lockout | Maximum ignition retries reached with no flame confirmed. Gas supply, flame sensor position, and combustion air are the usual causes. |
| Error 7 | Gas valve driver fault | Internal self-diagnostic failure in the gas valve circuit. |
| Error 10 | Flame signal out of sequence | Flame was sensed when it should not have been. |
| Error 11 | High-temperature cutoff (ECO) tripped | Water exceeded roughly 195°F; this is a one-time-use safety device. |
| Error 14 | Water temperature sensor fault | Sensor circuit is open or shorted. |
| Error 15 | Flammable vapors detected | Permanent lockout from the flammable-vapor sensor; requires a professional reset. |
Bradford White — White Rodgers Electronic Gas Control (FVIR Models)
Bradford White's own service manual for its current atmospheric-vent gas models documents two gas control generations. The older White Rodgers Electronic Gas Control uses a green LED with a similarly counted flash pattern to Rheem's Intelli-Vent, though the specific conditions differ.
| LED pattern | Control status | Probable cause |
|---|---|---|
| LED off | Control is off, burner off | Gas valve isn't powered — light the pilot. |
| 1 flash every 4 seconds | Pilot lit, main burner off | Normal — waiting for a call for heat, or the thermostat is satisfied. |
| 1 flash every second | Main burner lit | Normal operating heat cycle. |
| Solid ON | Control in shutdown | Setpoint knob was recently turned to off; wait for the LED to go out before relighting. |
| 2 flashes, 3-second pause | Low thermopile voltage | Loose thermopile connection or a weak pilot flame. |
| 4 flashes, 3-second pause | Temperature cutout reached | Water got too hot; verify control operation and reduce the setpoint. |
| 5 flashes, 3-second pause | Electronics, sensor, or valve fault | Check that all connections are tight; if the problem persists, the control needs replacement. |
Bradford White — ICON System Gas Control
Bradford White's current ICON System gas control (versions V1 and V2) is used across its newer residential atmospheric-vent gas water heaters. V2 adds color to the same LED — green for normal operation, yellow for low thermopile voltage, and red for a valve fault — on top of the flash-count pattern V1 introduced.
| LED pattern | Control status | Probable cause |
|---|---|---|
| LED off | Pilot not lit | Gas control isn't powered — light the pilot. |
| 1 flash, 3-second pause | Normal operation | Waiting for the setpoint knob, or the water heater is satisfied. |
| Solid ON | Control in shutdown | Setpoint knob was recently turned off; wait for the LED to go out. |
| 2 flashes, 3-second pause | Weak pilot signal | Thermopile failure, unstable pilot, or a blocked pilot tube. |
| 3 flashes, 3-second pause | Insufficient water heating | Thermal sensor out of calibration, or a faulty gas control. |
| 4 flashes, 3-second pause | Excessive tank temperature | Temperature sensor out of calibration, or a faulty gas control. |
| 5 flashes, 3-second pause | Temperature sensor fault | Sensor damaged, out of range, or unplugged. |
| 6 flashes, 3-second pause | Water leak detected | The accessory leak-detection module found water in the drain pan; check the T&P valve and all fittings. |
| 7 flashes, 3-second pause | Gas control electronic fault | Reset the control; replace it if the fault persists. |
| 8 flashes, 3-second pause | Standing pilot remains on with setpoint at OFF | Pilot valve stuck open — the gas control needs replacement. |
A.O. Smith and State
A.O. Smith and its sibling brand State take a different approach: rather than publish a single public status-light chart, both direct owners to a QR code on the water heater's rating plate that pulls up model-specific information, including the owner's manual and troubleshooting steps for that exact unit. We read the rating plate and pull the model-specific documentation before diagnosing an A.O. Smith or State gas control valve, the same way we do for any brand where the codes are model-specific rather than universal. That approach takes an extra step compared with reading a printed chart, but it means the information matches the unit in front of us instead of a generic model line.
When Repair Still Makes Sense, and When It Doesn't
ENERGY STAR's guidance is direct on age: once a water heater is past 10 years old, plan for replacement before it fails on its own schedule rather than yours. The warning signs it lists line up with what we see in the field — visible corrosion on the tank or fittings, water leaking from joints, seals, or seams, rust showing up in the hot water, a drop in available hot water from sediment buildup, and rumbling noises. Ignoring those signs risks a sudden failure, and in some cases a tank rupture and water damage, not just a cold shower.
None of that means every repair is a bad idea. A control valve, thermocouple, heating element, or thermostat failure on a unit under 8–10 years old is usually a straightforward, worthwhile repair — our water heater repairs start at $179 and most diagnoses happen on the first visit. The math changes once the unit is older or the failure is the tank itself: a leak from the tank shell means the inner tank has corroded through, and no repair fixes that. At that point we say so plainly rather than sell a repair that only delays the same decision.

Safety Comes Before Any Diagnosis
A locked-out gas valve or burner is a safety device doing its job — repeatedly resetting it without finding the cause is how a minor fault turns into a bigger one, and on some of the controls above, into a part that must be replaced rather than reset.
If you smell gas near a water heater, don't investigate it yourself: leave the area and call your gas utility or 911 from outside the home. If a carbon monoxide alarm sounds, get everyone out and call 911.
Sources: ENERGY STAR — When Should You Replace Your Water Heater · Bradford White — Homeowner FAQs · Bradford White Technical Bulletin — Hydrogen Sulfide Odor (Rotten Egg Smell) and Chlorinating Water Heaters · Bradford White Service Manual 238-51542-00 (Atmospheric Vent Gas, RG130T6N–RG250S6N) · Rheem/Ruud Technical Service Bulletin 1619 — Guardian PowerVent Flash Codes for Robertshaw Controls · Rheem/Ruud Technical Service Bulletin 1621 — White Rodgers Intelli-Vent Guardian PowerVent Control · A.O. Smith (hotwater.com) — Product Documentation Library · State Water Heaters — Support
Brand names and logos are trademarks of their respective owners, shown only to identify the equipment discussed. J&R Mechanical Services is an independent contractor and is not affiliated with or endorsed by these manufacturers.
Local & Independent
J&R Mechanical Services is an independent contractor — not a national franchise. Our technicians are not commissioned salespeople. We do the work you called us for, do it right, and earn the next call.

More Water Heaters Services
Serving Augusta & Brunswick
Water Heater Repair FAQs
Why do I suddenly have no hot water?
On gas units it is most often a pilot or ignition problem or a failed thermocouple; on tankless units, an error code from scale buildup or a flow sensor. Most of these are quick, affordable repairs.
My water heater is leaking — can it be fixed?
It depends where the water is coming from. Leaks at valves, fittings, or element gaskets are usually repairable. Water seeping from the tank body itself means the inner tank has corroded through, and replacement is the only fix. We will show you exactly which one you have.
Why does my pilot light keep going out?
The most common cause is a worn thermocouple — the safety sensor that holds the gas valve open — which is an inexpensive replacement. Draft problems, a dirty pilot orifice, or a failing gas control valve can also be responsible. It is a fast diagnosis for our technicians.
Do you service tankless water heaters too?
Yes — we diagnose error codes, descale heat exchangers, replace flow sensors and igniters, and service all major tankless brands, whether or not we installed the unit.
More Ways We Can Help
Google ReviewsServices
30Homeowners often pair this with our other offerings, including…
Service Areas
9Our primary service areas are Augusta and Brunswick, along with…
Company
5Get to know J&R Mechanical Services through…
Get a Quote
Request Service
Fill out the form below to request an estimate or schedule service.
“*” indicates required fields
Need it today?Call (207) 902-8899