Emergency Heating Repair
When your heat goes out during cold weather, it matters. J&R Mechanical Services handles boiler, furnace, and heat pump emergencies. Call us and we will talk through what is happening and get you on the schedule.
How a Furnace Works
- Return air — pulled in through the filter
- Blower — pushes air across the heat exchanger
- Burners — ignite to heat the exchanger
- Heat exchanger — transfers heat without mixing combustion gases
- Supply air — warm air delivered to the home
When to Call Right Away
- No heat — boiler or furnace will not fire
- Boiler leaking, losing pressure, or making loud noises
- Furnace blowing cold air or short-cycling
- Heat pump frozen, iced over, or not heating
- Frozen or burst pipes from a heating failure
A heating failure in cold weather is a real concern — frozen pipes, burst lines, and water damage can follow. The moment your heat stops, call us so we can talk through the situation and get you scheduled.
We diagnose the real problem and carry common parts to help finish repairs efficiently. If your system is beyond saving, we will tell you honestly and walk you through furnace, boiler, or heat pump replacement options.
Call Now
The fastest way to get help is to call.
(207) 902-8899Related Services
Reading Your Heating System: Codes, Lights, and What They Mean
When we get a call about a heating system, one of the first things we ask is what the display or lights are showing right now. Different brands report trouble in different ways: a blinking light, a two- or three-digit code on a small screen, or nothing visible at all. The five systems below cover oil and gas boilers, a gas combi-boiler, and a cold-climate heat pump, and each table is pulled straight from that manufacturer's own manual for the specific model line named.
Match your equipment's brand and, if you can find it, its model number to the sections below. A model number is usually on a metal or paper tag riveted or glued to the jacket or cabinet. If your system isn't listed here or the code doesn't match, write down exactly what the light or display is doing and call (207) 902-8899 — that detail is often the difference between one visit and two.
Oil-fired boilers — Weil-McLain WGO Series 4
The Weil-McLain WGO Series 4 is a cast-iron, oil-fired water boiler approved for Beckett (AFG or CF375), Carlin (EZ), or Riello burners, according to Weil-McLain's own product page. The boiler itself has no digital display — whatever burner is bolted to it does the reporting. That means two WGO boilers installed a year apart, by two different contractors, can show completely different lights or codes depending on which burner control came with them.
- Check that the thermostat is set to heat and a few degrees above room temperature.
- Check the emergency switch at the top of the basement stairs and the separate switch on the boiler itself — both look like ordinary light switches and are easy to bump off.
- Check the oil tank gauge. A boiler that ran dry needs the burner re-primed by a technician, not just a fuel delivery.
- See the next section for what the burner's own control lights mean.

Oil burner primary controls — Beckett GeniSys
Many oil burners on Weil-McLain and other cast-iron boilers use a primary safety control such as Beckett's GeniSys 7575, mounted directly on the burner with a reset button and three small lights. Those lights are the only diagnostic information most homeowners will ever see on an oil system.
| Light | On steady | Flashing |
|---|---|---|
| Red | Restricted (hard) lockout | Soft lockout |
| Green | Flame sensed / normal run | Recycle (lost flame, retrying) |
| Yellow | Pump-prime mode, or reset held 15+ seconds | Not used |
Per Beckett's manual, a soft lockout (flashing red) can be cleared with one click of the reset button. A hard lockout (steady red) means the control already tried and failed enough times that it is now limiting how much unburned oil can collect in the combustion chamber. Don't hold the reset button down repeatedly to force a restart — that's exactly the condition the hard lockout exists to prevent. Call for service instead.
Gas-fired condensing boilers — Burnham Alpine (Sage2.X control)
The Burnham Alpine high-efficiency condensing gas boiler, sold today under the U.S. Boiler Company name, uses a Sage2.X control with its own screen and a blinking Help button. U.S. Boiler's service manual splits problems into soft lockouts, which the boiler clears automatically once the cause is gone, and hard lockouts, which need a manual reset after the underlying issue is fixed.
| Code | Type | Meaning | Possible cause |
|---|---|---|---|
| 2 | Soft | Boiler safety limit open | Plugged condensate trap, or the boiler isn't level — check the trap first |
| 11 | Soft | Ignition failure after 5 tries | No gas pressure, or the gas line hasn't been fully purged of air |
| 6 | Hard | Flue (stack) temperature over 204°F | Heat exchanger needs cleaning, or the boiler is over-fired |
| 23 | Hard | 24V control power too high or low | Loose wiring or a failing transformer |
Select the blinking Help button on the Sage2.X display before you call — it names the exact lockout number, which saves a round of questions over the phone.
Combi (tankless) boilers — Navien NCB-E
The Navien NCB-E combines space heating and on-demand hot water in one unit and reports trouble as a three-digit E-code on its front panel. Navien's own troubleshooting chart lists more than twenty codes; the ones below are the situations we see most often in the field.
| Code | Meaning | What you can check |
|---|---|---|
| E003 | Ignition failure | Make sure the main gas supply valve is fully open |
| E012 | Flame loss | Clean the intake air filter; confirm the power cord is grounded |
| E110 | Abnormal air pressure | Clean the intake air filter; check the exhaust pipe for obstructions |
| E351 | Auto-feeder (make-up water) fault | Boiler couldn't restore water pressure within 5 minutes; needs a manual reset once the cause is found |
| E352 | High water pressure | Contact a technician — this is not a homeowner reset |
Navien's manual asks for the model number, serial number, and the exact error code before troubleshooting further — write those down from the front panel before you call anyone.

Cold-climate heat pumps — Daikin Aurora (FTX-WMVJU9 series)
Daikin's Aurora wall-mounted heat pump is rated by the manufacturer to heat down to 5°F standard, or -13°F to -25°F with factory options — the cold-climate performance that matters for a Maine winter. It has no screen on the indoor unit; instead, the operation light blinks in a pattern and the remote control can display a short self-diagnosis code.
- To read the code yourself: hold the temperature-down button on the remote for about 5 seconds until a small icon blinks, then press it repeatedly while pointing the remote at the indoor unit — a long beep confirms a matching code.
- If the operation light is on steady with no blinking, the unit is usually protecting itself from a brief power dip or blocked airflow and will often restart on its own in a few minutes.
| Code | Meaning |
|---|---|
| U0 | Refrigerant shortage |
| A5 | High-pressure control or anti-freeze protection tripped |
| E5 | Compressor overload or high-pressure switch activated |
| H0 | Sensor error |
| L3 / L4 / L5 | Outdoor unit overheated — check for a blocked or obstructed outdoor coil |

Sources: Weil-McLain WGO Series 4 oil-fired water boiler (product page) · Beckett GeniSys 7575 120V Control — Installation and Operation Manual · U.S. Boiler Company (Burnham) Alpine — Installation, Operating & Service Instructions · Navien NCB-E Owner's/User's Information Manual · Daikin Aurora (FTX09/12/15WMVJU9) Operation Manual
Brand names and logos are trademarks of their respective owners, shown only to identify the equipment discussed. J&R Mechanical Services is an independent contractor and is not affiliated with or endorsed by these manufacturers.
Emergency Heating Repair FAQs
What should I do while I wait for a technician?
Set the thermostat so you know the moment heat returns, open cabinet doors on exterior-wall plumbing, run a trickle of water from the farthest faucet, and only run space heaters on their own circuits. If you smell gas or oil, leave the house and call the utility first.
My boiler or furnace shows an error code — can you help over the phone?
Sometimes. Have the code, the brand, and a photo of the display ready when you call. Simple lockouts can occasionally be reset safely; if not, the technician arrives already knowing what parts to bring.
How long before pipes freeze in a house with no heat?
Pipes in exterior walls and unheated basements can freeze within a few hours once indoor temperatures drop well below freezing outside. That is why a no-heat situation should not wait — a frozen pipe turns a repair into a flood.
Do Not Wait — Call Now
The sooner you call, the less damage you face. J&R Mechanical Services handles heating and plumbing emergencies.
CALL (207) 902-8899More Ways We Can Help
Google ReviewsServices
30You can also count on us for…
Service Areas
9We serve Augusta, Brunswick, and towns throughout Kennebec & Cumberland County, including…
Company
5Helpful pages to start with include…
Not an Emergency? Request Service
Request Service
Fill out the form below to request an estimate or schedule service.
“*” indicates required fields
Need it today?Call (207) 902-8899